FixVault

Component Function Check

  1. VDC OFF INDICATOR LAMP OPERATION CHECK 1 

    Check that the lamp illuminates for approximately 3 seconds after the ignition switch is turned ON.

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Proceed to diagnosis procedure. Refer to Diagnosis Procedure .

  2. VDC OFF INDICATOR LAMP OPERATION CHECK 2 

    Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the VDC OFF switch.

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Check the VDC OFF switch. Refer to Component Inspection .