P2004

TUMBLE CONT/V

(Intake manifold runner control stuck open bank 1)

Diagnosis condition

-

Signal (terminal)

Intake manifold runner control valve position sensor signal

Threshold

The target angle of intake manifold runner control valve controlled by ECM and the input signal from intake manifold runner control valve position sensor is not in the normal range

Diagnosis delay time

5 seconds