Fail-Safe Function
|
DTC |
Vehicle behavior |
Vehicle condition |
|
P0705 P0706 |
|
-- |
|
P0713 |
The gear is fixed in a position of error detection |
During driving |
|
Locks in 3GR |
Other than the above |
|
|
P0717 P0720 |
|
During driving |
|
Other than the above |
|
|
P072C |
Locks in 2GR |
-- |
|
P072D |
Locks in 3GR |
-- |
|
P072E P072F |
The gear is fixed in neutral until vehicle speed decreases to below 5 km/h (3 MPH) and in 2GR when reaching 5 km/h (3 MPH) or more |
-- |
|
P0731 |
|
-- |
|
P0732 |
|
-- |
|
P0733 P0734 |
|
-- |
|
P073F |
|
-- |
|
P0740 P0743 P0744 |
Lock-up is prohibited |
-- |
|
P074A P074B |
|
-- |
|
P074C |
|
-- |
|
P0973 P0974 |
|
-- |
|
P0976 P0977 |
|
-- |
|
P0979 P0980 |
|
-- |
|
P0982 P0983 |
|
-- |
|
P2760 |
Slip lock-up is prohibited |
-- |
|
U0073 |
|
-- |
|
U0100 |
|
During driving |
|
Other than the above |
|
|
U0155 |
O/D OFF prohibited |
-- |
|
U0300 |
|
During driving |
|