FixVault

Fail-Safe Control By DTC

IPDM E/R performs fail-safe control when any DTC are detected.

DTC No.

CONSULT display

Fail-safe

B121A-11

FR FOG LAMP LH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the front fog lamp LH power supply circuit until the front fog lamp ON conditions are no longer satisfied.

B1231-11

DTRL RH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the daytime running light RH power supply circuit until the daytime running light ON conditions are no longer satisfied.

B1256-11

FR FOG LAMP RH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the front fog lamp RH power supply circuit until the front fog lamp ON conditions are no longer satisfied.

B20C7-11

A/C clutch

[CIRCUIT SHORT TO GROUND]

Inhibit compressor (magnet clutch) operation

B20C7-15

A/C clutch

[CIRC SHORT TO BATT OR OPEN]

B20C8-14

Compressor (ECV)

[CIRC SHORT TO GRND OR OPEN]

Inhibit compressor (ECV) operation

B20CB-11

DTRL LH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the daytime running light LH power supply circuit until the daytime running light ON conditions are no longer satisfied.

B20CE-11

HL (HI) LH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the headlamp (HI) LH power supply circuit until the headlamp (HI) ON conditions are no longer satisfied.

B20CF-11

HL (HI) RH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the headlamp (HI) RH power supply circuit until the headlamp (HI) ON conditions are no longer satisfied.

B20D0-11

HL (LO) LH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the headlamp (LO) LH power supply circuit until the headlamp (LO) ON conditions are no longer satisfied.

B20D1-11

HL (LO) RH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the headlamp (LO) RH power supply circuit until the headlamp (LO) ON conditions are no longer satisfied.

B20D2-11

PARKING LAMP PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the parking lamp (LH/RH) power supply circuit until the parking lamp ON conditions are no longer satisfied.

B20D4-11

TAIL LAMP LH PWR SPLY CIRC

[CIRCUIT SHORT TO GROUND]

Shuts off the power supply to the following power supply circuits until the parking lamp, license plate lamp, and tail lamp ON conditions are no longer satisfied.

  • Tail lamp LH
  • Tail lamp RH
  • License plate lamp LH
  • License plate lamp RH

B20E2-96

LED HEADLAMP RH

[CMPNENT INTERNAL MLFNCTN]

Transmits the headlamp warning signal (CAN communication) to the combination meter when the headlamp (LO) ON conditions are satisfied. (When the ignition switch is ON, the headlamp warning is displayed on the information display of the combination meter.)

B20E3-96

LED HEADLAMP LH

[CMPNENT INTERNAL MLFNCTN]

Transmits the headlamp warning signal (CAN communication) to the combination meter when the headlamp (LO) ON conditions are satisfied. (When the ignition switch is ON, the headlamp warning is displayed on the information display of the combination meter.)

U0073-00

Control module comm Bus A Off

[NO SUBTYPE INFO]

Refer to CAN COMMUNICATION CONTROL  of following.

U2140-87

CAN comm err (ECM)

[MISSING MESSAGE]

U214F-87

CAN comm err (BCM)

[MISSING MESSAGE]