FixVault

Work Procedure

  1. SYSTEM INITIALIZATION 
    1. Close the door.
    2. Power switch ON.
    3. Continue pulling the power window switch UP until glass stops at fully closed position then release the switch. *1
    4. Keep pulling the switch for 5 seconds or more. *2
    5. Continue pressing the power window switch DOWN until glass stops then release the switch.
    6. Keep pressing the switch for 5 seconds or more. *2. After glass moves again, keep pressing the switch until glass reaches the fully open position.
    7. Continue pulling the power window switch UP (MANUAL UP operation) until glass stops at fully closed position.
    8. Check that AUTO UP function operates normally.
    NOTE: SYMBOL *1: If the power window stops before reaching the fully closed position. After the power window stops, release the switch then continue pulling the switch UP again and move the power window to the fully closed position.

    *2: After keep pulling or pressing 5 seconds or more, glass moves again.

    >>

    GO TO 2.

  2. ANTI-PINCH INSPECTION 

    Check anti-pinch function. Refer to Description .

    >>

    END