Work Procedure

There is no vehicle specification in the new IPDM E/R, so the vehicle specification needs to be written in IPDM E/R with CONSULT.

Configuration has three functions as follows.

Function Description
Before ECU Replacement
  • Reads the vehicle configuration of current IPDM E/R
  • Saves the read vehicle configuration
After ECU Replacement FAST linked
NOTE: SYMBOL This item is displayed, but cannot be used
Manual selection Writes the vehicle configuration with manual selection.
CAUTION:

Never perform vehicle configuration other than performing with a new IPDM E/R or the control function may not operate normally.

  1. WRITING MODE SELECTION 
    1. SYMBOL CONSULT Reads the vehicle specification.

    When writing saved data (able to be read) >>

    GO TO 2.

    When writing manually (could not be read) >>

    GO TO 3.

  2. PERFORM WRITING SAVED DATA 
    1. SYMBOL CONSULT
      1. Ignition switch ON.
      2. Select "Re/programming, Configuration". Select the vehicle specifications saved with "Before ECU Replacement" and then write them to the replacement IPDM E/R.

    >>

    GO TO 5.

  3. PERFORM WRITING MANUALLY (IPDM E/R) 
    1. SYMBOL CONSULT
      1. Ignition switch ON.
      2. Select the "IPDM E/R" of "Re/programming, Configuration".
      3. Select the "Type ID" searched by using FAST (service parts catalog) to write the "Type ID" into the IPDM E/R.
        CAUTION:

        Check the "Type ID" accurately. If the "Type ID" is selected incorrectly, ECU control may not function normally.

    >>

    GO TO 4

  4. OPERATION CHECK 
    1. Confirm that each function controlled by IPDM E/R operates normally.

    >>