Component Description
FUNCTIONS WITHIN THE SYSTEM
- The system main relay 2 is integrated in the Li-ion battery and controlled by VCM.
- The system main relay 2 connects and disconnects the high-voltage circuit (-) side and Li-ion battery.
- When high voltage power is supplied, VCM activates the system main relay 2 to supply power from the Li-ion battery to the EV system.
- When charging, power from an external charger is supplied from the system main relay 2 to the Li-ion battery.
INDIVIDUAL FUNCTION WITHIN THE SYSTEM
The system main relay 2 connects and disconnects of the power supply circuit by ON / OFF of the relay switch.
COMPONENT LOCATION
The system main relay 2 is integrated in the Li-ion battery. The Li-ion battery is installed under the floor of the vehicle.