Amplifier & Temperature Dial Test
- This test uses the setup and connections of Step 3 of Tester Instructions. Disconnect both wires from amplifier. Voltage should go to 8 or 9 volts minimum and should go to zero when connecting the two terminals on amplifier together with a jumper wire or screwdriver.
- If voltage is as indicated in Step 1, replace temperature dial and rheostat assembly. If voltage did not change in Step 1, replace amplifier.
Courtesy of GENERAL MOTORS COMPANY
Courtesy of GENERAL MOTORS COMPANY