Engine Cooling Systems: OLDSMOBILE: Notes

CAPACITY (Qts.)

Application Non A/C A/C
Starfire    
  140" 4 Cyl. 8.5 8.5
  231" V6 13.5 14.0
Omega    
  250" 6 Cyl. 15.5 16.5
  260" V8 23.0 23.5
  350" V8 21.5 22.0
Cutlass    
  250" 6-Cyl. 17.0 17.0
  260" V8 23.5 23.5
  260" V8 Y72 26.0 26.0
  350" V8 20.0 20.0
  350" V8 Y72 22.5 22.5
  455" V8 21.0 21.5
  455" V8 Y72 23.5 23.5
"88"    
  350" V8 20.0 20.0
  350" V8 Y72 22.5 22.5
  455" V8 21.0 21.5
  455" V8 Y72 23.5 23.5
Crustom Cruiser & "98"    
  455" V8 21.0 21.5
  455" V8 Y72 23.5 23.5
Toronado    
  455" V8 21.5 21.5
THERMOSTAT

Application Opens Fully Opens
All Starfire 190°F 212°F
350" V8 Omega 190°F 212°F
All Others 195°F 222°F