FixVault

Automatic Choke

Loosen choke cover retaining screws and place cam follower on highest step of fast idle cam. Rotate choke cover against coil tension until choke valve just closes. Continue rotating cover until reference mark on cover is aligned with specified mark on choke housing. Tighten cover retaining screws.

1975 AUTOMATIC CHOKE SETTINGS

Application Setting
260" 1 NR
350"
  Omega 1 NR
Cutlass & 88 2 NR
400" Index
455"
  California 2 NR
Federal 2 NR
1976 AUTOMATIC CHOKE SETTINGS

Application Setting
2GC 1 NR
2MC
  17056456, 17056457 & 17056459 Index
All Others 1 NR
M4MC
  17056546 Index
17056246, 17056551 & 17056556 1 NR
All Others 2 NR
1977 AUTOMATIC CHOKE SETTINGS

Application Setting
260" 2-Bbl. (1) 1 NR
305" 2-Bbl.
  California 1NL
Federal Index
High Altitude Index
305" 2-Bbl. Index
350" 4-Bbl. (VIN L) 2NL
350" (VIN R) & 403" 4-Bbl. 2 NR
(1) Setting on 88 is 2 NR.
1978 AUTOMATIC CHOKE SETTINGS

Application Setting
260" 2-Bbl. 2 NR
305" 2-Bbl. (VIN U)
  California 1/2NL
Federal Index
High Altitude Index
305" 4-Bbl. (VIN H) 2NL
350" 4-Bbl. (VIN L) 2NL
350" (VIN R) & 403" 4-Bbl. 2 NR
1979 AUTOMATIC CHOKE SETTINGS

Application Setting
260" & 301" 2-Bbl. 2 NR
305" 2-Bbl. 1 NR
305" 4-Bbl. (1) 1 NR
350" 4-Bbl. (VIN L)
  Calif. 2 NR
High Alt. 1 NR
350" (VIN R) & 403" 4-Bbl. 2 NR
(1) Setting on Cutlass is 2 NR.