FixVault

System Operational Test

  1. Unload vehicle. With ignition off, check riding height. Turn ignition on (engine off). Reset "running time" by starting and running vehicle for a brief period of time.
  2. Add a 300 lb. (136 kg) load to trunk. Compressor should start operating within 27 seconds. Vehicle should rise to within 3/4" (19 mm) of riding height. Compressor should stop within 2 minutes.
  3. Remove load from trunk. Exhaust should start within 27 seconds. Within 2 minutes, exhaust should stop and vehicle should be within 3/4" (19 mm) of riding height.