FixVault

Note On Intermittents:

If an intermittent Code B131 is being set, manipulate circuit No. 313. When BCM input BI26 change-of-state indicator displays an "X", the failure has been induced.

Fig 1: Code B131, Engine Oil Pressure Switch Circuit Problem
G6157
Fig 2: Code B131, Schematic