FixVault

Washer Fluid Is Low Message

The BCM supplies and monitors voltage at terminal 2A4. When fluid level circuit is open, BCM will sense high voltage. When fluid level circuit is closed (low washer fluid), BCM will sense low voltage and illuminate WASHER FLUID IS LOW message. BCM will illuminate message if low washer fluid exist for at least 15 seconds.

Fig 1: Washer Fluid Is Low Message Circuit Diagram
G90F14410