FixVault

Diagnostic Aids

Verify a clean, tight connection for the sensor ground. An open circuit at sensor signal terminal or ground terminal will result in a Code 13.

CODE 13 TERMINAL & CIRCUIT WIRING IDENTIFICATION

Application PCM Terminal Wire Color
Oxygen Sensor Signal D7 Purple
Oxygen Sensor Ground D6 Tan
Fig 1: Code 13 Schematic (3.1L) Open Oxygen Sensor Circuit
G91H07378
Fig 2: Code 13 Flow Chart (3.1L) Open Oxygen Sensor Circuit
G91B07281