FixVault

Test Description

NOTE: Test numbers refer to numbers on diagnostic chart (2 Of 2).
  1. Checks will diagnose an incorrect EGR pintle position sensor input signal. This test verifies a 5-volt reference at EGR valve.
  2. Ensures position signal circuit is not shorted to ground.
  3. Checks position signal circuit for an open.
Fig 1: Code P1406 Diagnostic Flow Chart - 2 Of 2 (3.8L) EGR Valve Pintle Position
G94A35287