FixVault

PASSLOCK(R) Learn Procedures

NOTE: Perform the Passlock(R) learn procedure when the Passlock(R) sensor, BCM or PCM have been replaced. Program replaced module before programming Passlock(R).
  1. Turn ignition ON.
  2. Turn ignition to CRANK, and then back to ON without starting vehicle.
  3. Observe SECURITY indicator for 10 minutes.
  4. After ignition has been on for 10 minutes, the SECURITY indicator will switch from on to off.
  5. Using scan tool, clear DTCs.