FixVault

Water Pump: Notes

COOLING SYSTEM CAPACITY

Application Quarts
225" 6 Cyl.
  All Pick-up Models (2)12
B100, B200, PB100, PB200, B300, PB300, CB300, CB400, MB300, MB400,
    Man. Trans (3)12
Auto. Trans (3)14
With A/C or Max. Cooling (3)15
318" V8
  All Pick-up Models (1)16
B100, B200, PB100, PB200,
    Man. Trans. (2)(3)16
Auto. Trans. (2)(3)16
  B300, PB300, CB300, CB400, MB300, MB400,
    Standard Models (2)(3)16
With Maximum Cooling (3)19
  B200, PB200, B300, PB300,
    With A/C & Trailer Pkg. (3)19
360" V8
  All Pick-up Models (1)14.5
  B100, B200, PB100, PB200,
    Standard (1)(3)16
  B300, PB300, CB300, CB400, MB300, MB400,
    Standard (1)(3)17
  B200, PB200, B300, PB300,
    With A/C & Trailer Pkg. (3)19
(1) Add 1 quart with A/C or increased cooling.
(2) Add 2 quarts with A/C.
(3) Add 1 quart with auxiliary heater.
PRESSURE CAP

Application PSI
All Models 16
THERMOSTAT

Application (1)Initial Open (1)Full Open
225" All Models 192-199 219
318" All Models 192-199 219
360" All Models 192-199 219
(1) Specifications are in °F.