Purge Control Solenoid Valve
- Purge Control Solenoid Valve is located on left center of firewall. Label and disconnect both vacuum hoses from solenoid valve. Disconnect electrical connector. Connect hand vacuum pump to solenoid valve nipple where Red-striped hose was connected. Apply vacuum to solenoid valve. Vacuum should hold.
- Apply battery voltage to terminals of solenoid valve. Vacuum should bleed down when voltage is applied to terminals. Using an ohmmeter, check resistance across solenoid valve terminals. Reading should be 36-44 ohms at 68°F (20°C). If reading is not within specification, replace valve.