MANIFOLD AIR TEMPERATURE (MAT) SENSOR RESISTANCE TEST
(1)
Temperature °F (°C)
Ohms
210 (100)
185
160 (70)
450
100 (38)
1800
70 (20)
3400
40 (4)
7500
20 (-7)
13,500
0 (-18)
25,000
-40 (-40)
100,700
(1)
Measure resistance between terminals of sensor.