FixVault

Code 45, Rich Exhaust Indication: Notes

NOTE: Test numbers refer to test numbers on diagnostic chart.
  1. Code 45 is set when O2 sensor signal at ECM is greater than .75 volt for 50 seconds and system is in "closed loop".