FixVault

Charging System Check

  1. Check battery and battery cables. Check STRTR, IGN, and GAGES fuses in instrument panel fuse block. Check system grounds. Check starter connections. Check drive belt. Turn ignition switch to START position. If engine cranks, go to next step. If starter solenoid does not click or starter solenoid clicks, but engine does not crank, diagnose starter. See STARTER article.
  2. Start engine. Check voltage at battery. If voltage reads 13-16 volts, system is okay. If voltage is not 13-16 volts, proceed to BATTERY IS UNDERCHARGED OR OVERCHARGED  .