End Play Check

Mount Torque Converter End Play Fixture (J-35138) and Dial Indicator (J-8001) on torque converter to check end play. End play should be 0-.020" (0-.50 mm). See Fig 1.

Fig 1: Measuring Torque Converter End Play
G92C12718Courtesy of GENERAL MOTORS CORP.