FixVault

Typical Scan Tool Data

WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Starter Relay Ckt Short Gnd Test Status - ECM

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Cranking
Parameter Normal Value:  OK*
STRTR Relay Control Fault OK OK
Ground - OK -
*The parameter displays Not Run when not cranking.
Starter Relay Ckt Open Test Status - ECM

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON
Parameter Normal Value:  OK*
STRTR Relay Control OK Fault Fault
Ground - Fault -
*The parameter displays Not Run when cranking.
Starter Relay Ckt Short Volts Test Status - ECM

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON
Parameter Normal Value:  OK*
STRTR Relay Control OK Fault Fault
Ground - Fault -
*The parameter displays Not Run when cranking.