FixVault

Assembly Procedure

  1. Install the flow control spring (2) to the hydraulic pump housing assembly (1).
  2. Install the control valve assembly (3).
  3. Lubricate the O-ring seal (4) with power steering fluid.
  4. Install the O-ring seal (4) onto the O-ring union fitting (5).
  5. Install the O-ring union fitting (5) into the hydraulic pump housing assembly (1).

    Tighten 

    Tighten the fitting (5) to 75 N.m (55 lb ft).

Fig 1: Installing Control Valve Assembly
G01499335Courtesy of GENERAL MOTORS CORP.