Removal Procedure
- Using a scan tool, retrieve the percentage of remaining engine oil. Record the remaining engine oil life.
- Turn OFF the ignition.
- Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure
in Engine Electrical.
- Remove the intake duct. Refer to Air Cleaner Intake Duct Replacement .
Courtesy of GENERAL MOTORS CORP.
- Remove the 2 screws (2) from the upper and lower air cleaner assembly sections.
- Remove the upper air cleaner housing assembly (1).
Courtesy of GENERAL MOTORS CORP.
- Without disconnecting the PCM connectors (1), remove the PCM (3) and harness from the PCM housing (2).
- Disconnect the PCM connectors (1).