FixVault

Installation Procedure

    Fig 1: Identifying HO2S Electrical Connector
    GM73896Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice in Cautions and Notices.
    NOTE: A special anti-seize compound is used on the oxygen sensor threads. New service sensors should already have the compound applied to the threads. Coat the threads of a reused sensor with anti-seize compound P/N 5613695 or equivalent.
  1. Install the heated oxygen sensor (HO2S).

    Tighten:  Tighten the HO2S 1 to 41N.m (30 lb ft).

  2. Lower the vehicle.
  3. Connect the electrical connector.