Scan Tool Output Controls
Scan Tool Output Controls
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| A/C Relay | Engine Output Controls/A/C Relay | Activates the A/C compressor relay. The normal commanded state of the A/C relay is NONE. |
| A/C LED | Body/BCM/A/C LED | Activates the A/C LED indicator. The normal commanded state of the A/C LED is OFF. |
| Cooling Fan | Engine Output Controls/Cooling Fan | Activates the cooling fan 1 by enabling the fan relay 1. The normal commanded state of the relay is NONE. The ECM allows relay control when the following conditions are met:
|
| Fan Relay 1 | Engine Output Controls/Fan Relays | Activates the cooling the fan 1 by enabling fan relay 1. The normal commanded state of the relay is NONE. The PCM allows relay control when the following conditions are met:
|
| Fan Relays 2 and 3 | Engine Output Controls/Fan Relays | Activates the cooling fan 2 by enabling fan relay 2. The normal commanded state of the relay is NONE. The PCM allows relay control when the following conditions are met:
|
| Fan Relays 1, 2 and 3 | Engine Output Controls/Fan Relays | Activates the cooling fan 2 by enabling fan relay 2. The normal commanded state of the relay is NONE. The PCM allows relay control when the following conditions are met:
|