FixVault

Removal Procedure

    Fig 1: View Of IAT Sensor Harness Connector
    GM851290Courtesy of GENERAL MOTORS CORP.
  1. Disconnect the intake air temperature (IAT) sensor harness connector.
  2. Loosen the air cleaner assembly fresh air duct to resonator clamp.
  3. Fig 2: View Of Air Cleaner Outlet Resonator
    GM851256Courtesy of GENERAL MOTORS CORP.
  4. Remove the push-pin fastener from the air outlet resonator/duct assembly to support bracket.
  5. Loosen the resonator to throttle body clamp.
  6. Disconnect the air cleaner assembly fresh air duct from the resonator.
  7. Remove the air outlet resonator from the throttle body.