FixVault

Component Testing

IMPORTANT: You must perform the circuit/system testing, in order to verify the integrity of the MAP sensor circuits, before proceeding with the component testing.

Erratic Signal Test

  1. Ignition OFF, remove the MAP sensor.
  2. Install a 3A fused jumper wire between the 5-volt reference circuit terminal C and the corresponding terminal of the MAP sensor.
  3. Install a jumper wire between the low reference circuit terminal A of the MAP sensor and ground.
  4. Install a jumper wire at terminal B of the MAP sensor.
  5. Connect a DMM between the jumper wire from terminal B of the MAP sensor and ground.
  6. Install the J 23738-A  or J 35555  to the MAP sensor vacuum port. Slowly apply vacuum to the sensor while observing the voltage on the DMM. The voltage should vary between 0-5.2 volts, without any spikes or dropouts.
    • If the voltage is erratic, replace the MAP sensor.