Circuit Description
During calibration of the offset of the pressure sensor signal, the pressure sensor signal offset value must be in the range of 1-15 Bar (1-434 psi).
The pressure sensor is also monitored for sensitivity via a correlation between estimated vehicle deceleration and the pressure sensor signal. This is monitored over the course of numerous straight line non antilock brake system (ABS) braking stops.