Installation Procedure
- Align the inflatable restraint I/P module to the I/P trim pad.
- Install the inflatable restraint I/P module nuts.
Tighten: Tighten the nuts to 10 N.m (89 lb in).
- Route the PSIR wire harness under the locating rib and attach the metal edge clips to the I/P trim pad.
- Install the I/P trim pad. Refer to Instrument Panel Trim Pad Replacement .
- Install the inflatable restraint I/P module bracket bolts.
Tighten: Tighten the bolts to 10 N.m (89 lb in).
- Install the I/P compartment. Refer to Instrument Panel Compartment Replacement .
- Enable the SIR system. Refer to SIR Disabling and Enabling .
NOTE:
Refer to Fastener Notice
.