FixVault

Installation Procedure

IMPORTANT: Rotate the pigtail 90 degrees from vertical before securing the fastener.
    Fig 1: Identifying Knock Sensor & Bolt
    GM1578476Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice .
  1. Install the KS.
  2. Install the KS bolt.

    Tighten:  Tighten the bolt to 25 N.m (18 lb ft).

  3. Fig 2: Locating KS Electrical Connector
    GM1590505Courtesy of GENERAL MOTORS CORP.
  4. Disconnect the KS electrical connector (3).
  5. Install the KS electrical connector clip to the oil level indicator tube bracket.