FixVault

Typical Scan Tool Data

AIR Pressure Sensor

Circuit Short to Ground Open Short to Voltage
Parameter Normal Range:  BARO
Operating Conditions:  Engine running under various operating conditions
5 V Reference 41 kPa (5.9 psi) 41 kPa (5.9 psi) 111 kPa (16.1 psi)
AIR Pressure Sensor Signal 42 kPa (6.1 psi) 41 kPa (5.9 psi) 150 kPa (21.8 psi)
Low Reference - 145 kPa (21 psi) -