FixVault

911 Carrera

  1. Oxygen sensor must be connected. Connect an analog dwell meter or voltmeter to the idle stabilizer test pins A and C. See Figure
  2. Start the engine. The display panel of test meter must jump between 0-100% dwell or 0-12 volts. If the display does not change in 6 seconds, check for problem in oxygen sensor circuits.
Fig 1: Diagram of 944 DME System Distributor Align distributor cap with its locking boss facing up.
G42096