  1. Reconnect the fuel pressure regulator vacuum hose. Disconnect the oxygen sensor. Connect the oxygen sensor harness connector terminal to ground.
  2. Check if the CO% level increases. If not, check wire from CU connector terminal No. 24 to oxygen sensor plug. If no problem is found, replace the oxygen sensor.