FixVault

Control position not adjustable: Diagnosis/troubleshooting

DIAGNOSIS/TROUBLESHOOTING PROCEDURE

Work instruction Display OK If not OK
1 Check mechanical and pneumatic components Go to Step 3 Repair/replace components in accordance with procedures in
LEVEL CONTROL article .
Go to Step 2
2 Check to see if other faults are recorded (e.g. 0774,0775,0776,1780) Go to Step 4 Correct faults and read out fault memory for level control module again.
If OK:
→ End
If not OK:
→ Step 3
3 Re-calibrate level control module
Calibrating level control module, refer to 43 K2 CALIBRATION - AS OF MY 2003 (ALL MODELS EXCEPT CAYENNE S TIO TITAN) .
→ End Go to Step 4
4 Replace level control module → End