FixVault

Diagnosis/troubleshooting G 0210

NOTE: If there is no incoming signal/message via the CAN drive using several control units, the CAN drive must be checked for open or short circuits. Refer to 'CHECKING INSTRUCTIONS/CAN DATA BUS '.
DIAGNOSIS/TROUBLESHOOTING PROCEDURE

Work instruction Display OK If not OK
1 Check DME control unit coding and correct it if necessary → End
2 Read out fault memory for DME control unit (fault localization) For further troubleshooting, please follow the diagnosis instructions for the DME control module in FUEL SYSTEM, ELECTRONIC INJECTION .
→ End
3 CHECKING INSTRUCTIONS/CAN DATA BUS . → End