FixVault

Fault code 0576: Diagnosis/troubleshooting

DIAGNOSIS/TROUBLESHOOTING PROCEDURE

Work instruction Display OK If not OK
1 Check fuse:
  • Switch off ignition.
  • Remove fuse F41 (10A) from fuse carrier at left of dashboard and check it for continuity.
< 5 Ω
Go to Step 2
Replace fuse.
→ End
2 Check wiring to fuse and from fuse to control module for open circuit and short circuit to B+: Go to Step 3 Repair wiring or replace wiring harness.
→ End