Removing Side Section Flap (Module)
IMPORTANT:
The side section flap module will be damaged during removal and must be replaced during installation.
- Loosen emergency release > Emergency release on the fuse box.
Emergency release
- 1.1 Remove cover on fuse box.
- 1.2 Unclip emergency release latch (cable) on the fuse box -Arrow- .
- Open side section flap.
- Loosen side section flap -arrows-
.
Side panel flap (module)
- 3.1 At the marked positions -arrows- , pierce the module using a screwdriver.
- Loosen side section flap > Side panel flap (module).
Side panel flap (module)
- 4.1 Pierce the module using a screwdriver -arrow A-.
- 4.2 Release locking lugs on inner part of side section flap (module) -arrow B- .
- Remove side section flap (module) > Side panel flap (module).
Side panel flap (module)
- 5.1 Swivel side section flap (module) > Side panel flap (module) out of the body aperture until the electric plug connections -1 and 2- are accessible.
- 5.2 Release and unplug electric plug connections -1 and 2-.
- 5.3 Pull drain hose -3- off the side section flap (module) > Side pane flap (module).
- 5.4 Remove side section flap (module) > Side pane flap (module).
- Remove actuator -1-
and charging operator control unit -2-
.
Removing actuator and charging operator control unit
- 6.1 Unclip actuator -6- and charging operator control unit -2- (-Arrows-) .
- 6.2 Remove actuator -1- and charging operator control unit -2- .