WARNING: Combination sensor not calibrated or calibrated incorrectly 
  • Unexpected vehicle handling 
  • Combination sensor does not work 
  • Malfunction in combination sensor 
    • Calibrate the vehicle after installing or replacing the combination sensor using > 9818 - PIWIS Tester II. 
    • Only perform calibration when the vehicle is positioned horizontally and the brake is not actuated.
  1. Calibrate rotation-rate sensor using > 9818 - PIWIS Tester II. 

    To do this, select:

    • Control unit overview 
    • PSM 
    • Maintenance/repairs 
    • Select Sensor cluster calibration (combination sensor)  and start calibration.

      Calibration is then complete.

  2. Only for vehicles with manual transmission (I-no. 480) 

    Install gearshift bracket.

    > 340819 REMOVING AND INSTALLING GEARSHIFT BRACKET

  3. Only for vehicles with PDK (I-no. 250) 

    Install selector support.

    > 370819 REMOVING AND INSTALLING SELECTOR SUPPORT