WARNING: Combination sensor not calibrated or calibrated incorrectly 
  • Unexpected vehicle handling 
  • Combination sensor does not work 
  • Malfunction in combination sensor 

    → Calibrate the vehicle after installing or replacing the combination sensor using > 9818 - PIWIS Tester II 

    → Only perform calibration when the vehicle is positioned horizontally and the brake is not actuated.

  1. Calibrate rotation-rate sensor using > 9818 - PIWIS Tester II 

    To do this, select:

    → Control unit overview 

    → PSM 

    → Maintenance/repairs 

    → Select Sensor cluster calibration (combination sensor)  and start calibration

    Calibration is then complete.

  2. Only for vehicles with manual transmission (l-no. 480) 

    Install gearshift bracket.

    > 340819 REMOVING AND INSTALLING GEARSHIFT BRACKET

  3. Only for vehicles with PDK (l-no. 250) 

    Install selector support.

    > 370819 REMOVING AND INSTALLING SELECTOR SUPPORT