FixVault

Float Level Adjustment

With carburetor upper body removed and held in a vertical position with float hanging down, measure distance from float bottom to the upper body gasket and adjust (see specifications ) by bending tab resting against the needle valve.

Fig 1: FLOAT LEVEL ADJUSTMENT
G09309793Courtesy of NOT AVAILABLE