FixVault

Main relay, engine control system (229)

Fig 1: Identifying Main Relay For Engine Management System
G05052559Courtesy of SAAB-SCANIA OF AMERICA, INC.
RESISTANCE SPECIFICATIONS

Resistance, winding at 20°C (68°F) Ohm 85 ± 5
Nominal control voltage V 12
Nominal current A 30