FixVault

To remove

Fig 1: Illustration For Step 2-3
G05035132Courtesy of SAAB-SCANIA OF AMERICA, INC.
IMPORTANT:

Remove out fuse 19 while the engine is idling to minimize any remaining fuel pressure. Turn off the ignition when the engine has stopped.

  1. Unplug the connectors to the oxygen sensor and crankshaft position sensor.
  2. Detach the vacuum hose.
  3. Remove the bolt and open the clamp.
  4. Gently work loose the pressure regulator.