FixVault

Circuit/System Testing

  1. Verify that a test lamp illuminates between the G13 Generator B+ terminal A X1 and ground.
  2. If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  3. Ignition OFF, disconnect the X2 harness connector at the G13 Generator.
  4. Ignition ON, verify the scan tool Generator F-Terminal Signal parameter displays less than 5%.
  5. If greater than the specified range, test the signal circuit terminal 2 for a short to voltage. If the circuit tests normal, replace the K20 Engine Control Module.
  6. Install a 3 A fused jumper wire between B+ and the signal circuit terminal 2.
  7. Verify the scan tool Generator F-Terminal Signal parameter displays greater than 95%.
  8. If less than the specified range, test the signal circuit terminal 2 for a short to ground or an open/high resistance. If the circuit tests normal, replace the K20 Engine Control Module.
  9. If the circuit tests normal replace the G13 Generator.