To remove
- Remove Transfer case, B284 or Transfer case, B207 .
- Fit the transfer case in 78 74 878 Floor stand, using 32 025 053 Holder (EN-47642).
IMPORTANT: Circlip opening towards "whole" surface.
- Remove the outer circlip (A) from the housing.
- Tap out the intermediate shaft (A) with a rubber mallet.
- Remove the circlips (A) and (B).
- Remove the bearing (C), using tool 87 90 982 Ring, pinion bearing (D) to press off the bearing.