FixVault

Diagnostic Aids

To locate an intermittent problem, use scan tool to monitor DTC P1669 LAST TEST with engine running. Wiggling wires while watching for a change from PASSED to FAILED may locate the area where an open, short to ground or short to voltage on Orange/Black wire exists.

If a fault exists on Orange/Black wire, the EBTCM will not set a DTC.