Installation Procedure
- Install the surge tank.
- Connect the coolant level sensor electrical connector.
- With the surge tank raised, install the surge tank outlet hose.
- Reposition the hose clamp using SA9111E to secure the hose. See Special Tools and Equipment .
- Install the surge tank bolt.
Tighten: Tighten the bolt to 8 N.m (70 lb in).
- Set the underhood junction block bracket into position.
- Install the underhood junction block bracket nuts (1,2).
Tighten: Tighten the nuts to 10 N.m (88 lb in).
- Install the underhood junction block bracket bolt (3).
Tighten: Tighten the bolt to 25 N.m (18 lb ft).
- Install the surge tank inlet hose to the surge tank.
- Reposition the hose clamp to secure the hose.
- Fill the cooling system. Refer to Draining and Filling Cooling System (2.2L (L61)) or Draining and Filling Cooling System (2.0L (LSJ)) .
NOTE:
Refer to Fastener Notice
in Cautions and Notices.