FixVault

Installation Procedure

    Fig 1: Control Assembly & Nuts
    GM944361Courtesy of GENERAL MOTORS CORP.
  1. Install the control assembly.
  2. NOTE: Refer to Fastener Notice in Cautions and Notices.
  3. Install the control assembly bolts.

    Tighten:  Tighten the control assembly to bracket bolts to 25 N.m (18 lb ft).

  4. Fig 2: Control Assembly Electrical Connectors
    GM944353Courtesy of GENERAL MOTORS CORP.
  5. Connect the control assembly electrical connectors.
  6. Fig 3: Indicator Bulb
    GM945404Courtesy of GENERAL MOTORS CORP.
  7. Install the indicator bulb by inserting and rotating one-quarter turn.
  8. Fig 4: Park Lock Cable Assembly & Pin On Control Assembly
    GM944348Courtesy of GENERAL MOTORS CORP.
  9. Install the park lock cable onto the control assembly using a new clip.
  10. Connect the park lock cable onto the control assembly pin.
  11. Fig 5: Shifter Cable & Control Assembly Pin
    GM944208Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: The secondary clip is not required for service. Make sure the shifter cable is fully engaged into the shiftier control.
  12. Install the shifter cable onto the control assembly. Secure with a new shiftier cable retainer clip.
  13. Connect the shifter cable onto the control assembly pin.
  14. Install the console. Refer to Console Replacement in Instrument Panel, Gages, and Console.
  15. Enable SIR system. Refer to SIR Disabling and Enabling Zone 8 in SIR.