Removal Procedure

  1. Disconnect the intake air temperature (IAT) sensor connector
    Fig 1: Disconnecting Intake Air Temperature (IAT) Sensor Connector
    GM951542Courtesy of GENERAL MOTORS CORP.
  2. Loosen the clamp at the air cleaner assembly.
  3. Remove the push pin attachment from the outlet resonator/duct assembly to support bracket.
    Fig 2: Positioning Outlet Resonator/Duct Assembly
    GM897621Courtesy of GENERAL MOTORS CORP.
  4. Loosen the clamp at throttle body assembly.
  5. Disconnect the PCV fresh air vent hose at cam cover.
  6. Remove the outlet resonator/duct assembly.